Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters

Database
Language
Document Type
Year range
1.
SAGE Open Med Case Rep ; 11: 2050313X231154064, 2023.
Article in English | MEDLINE | ID: covidwho-2253036

ABSTRACT

During the coronavirus disease 2019 pandemic, Ecuador reported a collapse of the healthcare system, in which intensive care unit beds were lacking. Therefore, we sought to determine whether the use of threshold expiratory positive pressure with an adult non-rebreather oxygen mask plus prone positioning is useful for improving oxygenation. Twelve patients were included. Eight patients (66.7%) survived, while four patients (33.3%) died. Baseline arterial oxygen saturation (%) prior placement median (interquartile range) 85.5% (80%-89%) and arterial oxygen saturation (%) post placement of the device was median (interquartile range) (93%-96%) (P = 0.0001). Respiratory rate before placement was median (interquartile range) 38 (36-42) and post placement of the device was median (interquartile range) 24 (22-30) (P = 0.0005). The use of an adapted device might be useful for the management of acute hypoxemic respiratory failure due to severe acute respiratory syndrome coronavirus 2 pneumonia, particularly when mechanical ventilators and high-flow oxygen systems are unavailable.

SELECTION OF CITATIONS
SEARCH DETAIL